SCH601MDE

Airolite louver type SCH601MDE is a sightproof, horizontal blade storm class Louver that is Florida Building Code approved for use in the High Velocity Hurricane Zone and Miami-Dade approved for installations where the enclosed space is designed to drain or otherwise accommodate water penetration (wet rooms).

Specifications Hide all

General
Beginning Point of Water Penetration above 1,250 fpm (6.35 m/s)
Pressure Drop at Beginning Point of Water Penetration 0.32 in. wg (0.081kPa)
Test Standard AMCA Standard 500-L Water Penetration, Air Performance and Wind Driven Rain, AMCA 540 Test Method for Louvers Impacted by Wind Borne Debris (Basic Protection, Missile Level D and Enhanced Protection, Missile Level E), Florida Test Protocol: TAS 201 Large Missile Impact, Florida Test Protocol: TAS 202 Uniform Static Air Pressure, Florida Test Protocol: TAS 203 Cyclic Wind Loading
Percent Free Area 47% (4 ft. x 4 ft.)
Louver Depth 6" (152.4 mm)